Evc Configuration - FibroLAN Falcon Gen-3 M-Class User Manual

Table of Contents

Advertisement

Falcon M-Class | User Guide
4.9.5

EVC Configuration

This section displays current EVC configurations. The settings can also be configured here
Figure 4-66: EVC Configuration displays
Table 4-63: EVC Parameters
EVC Configuration
NNI Ports
EVC Parameters
EVC ID
VID
IVID
The list of Network to Network Interfaces for the EVC
The EVC ID identifies the EVC. The range is from 1 through 128.
The VLAN ID in the PB network. It may be inserted in a C-tag, S-tag or
S-custom tag depending on the NNI port VLAN configuration. The
range is from 1 through 4095.
The Internal/classified VLAN ID in the PB network. The range is from 1
through 4095.