Delay Measurements Bins

A Measurement Bin is a counter that stores the number of delay measurements falling within a
specified range, during a Measurement Interval.
Figure 4-201: Delay Measurement Bins
Table 4-176: Delay Measurement Bins Parameters
Measurement Bins for FD
Configurable number of Inter-Frame Delay Variation Measurement Bins per Measurement
Interval.
The minimum number of FD Measurement Bins per Measurement Interval supported is 2.
The maximum number of FD Measurement Bins per Measurement Interval supported is 10.
The default number of FD Measurement Bins per Measurement Interval supported is 3.
Measurement Bins forIFDV
Configurable number of Inter-Frame Delay Variation Measurement Bins per Measurement
Interval.
The minimum number of FD Measurement Bins per Measurement Interval supported is 2.
The maximum number of FD Measurement Bins per Measurement Interval supported is 10.
The default number of FD Measurement Bins per Measurement Interval supported is 2.
Measurement Threshold
Configurable the Measurement Threshold for each Measurement Bin.
The unit for a measurement threshold is in microseconds (us).
The default configured measurement threshold for a Measurement Bin is an increment of
5000 us.
Buttons
Refresh: Click to refresh the page immediately
Save: Click to save changes
Reset: Click to undo any changes made locally and revert to previously
saved values
Back: Click to go back to this MEP instance main page