Three-Phase 400 V Class Drive Models 4A0208 to 4A0675

Item
Drive Models
Maximum Applicable Motor Capacity
<1>
(HP)
Input Current (A)
Rated Voltage
Input
Rated Frequency
Allowable Voltage Fluctuation
Allowable Frequency Fluctuation
Input Power (kVA)
Rated Output Capacity
<4>
(kVA)
Rated Output Current (A)
Overload Tolerance
Output
Carrier Frequency
Maximum Output Voltage (V)
Maximum Output Frequency (Hz)
<1> The motor capacity (HP) refers to a NEC rated 4-pole motor. The rated output current of the drive output amps should be equal to or greater than
the motor current. Select the appropriate capacity drive if operating the motor continuously above motor nameplate current.
<2> Assumes operation at the rated output current. Input current rating varies depending on the power supply transformer, input reactor, wiring conditions,
and power supply impedance.
<3> DC is not available for UL/CE standards.
<4> Rated motor capacity is calculated with a rated output voltage of 440 V.
<5> Carrier frequency default setting is Swing PWM 1 (C6-02 = 7). C6-02 settings 1, 7, 8, 9, and A do not require current derating. All other settings
raise the carrier frequency and require current derating.
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
Table A.6 Power Ratings Continued (Three-Phase 400 V Class)
4A0208
ND Rating
150
<2>
ND Rating
207
ND Rating
189
<5>
159
ND Rating
<5>
208
ND Rating
User-adjustable between 1 and 10 kHz
Specification
4A0250
4A0296
4A0362
200
250
248
300
Three-phase: 380 to 480 Vac 50/60 Hz/510 to 680 Vdc
-15 to 10%
227
274
191
226
250
296
ND Rating: 120% of rated output current for 60 s
(Derating may be required for applications that start and stop frequently)
Three-phase: 380 to 480 V (proportional to input voltage)
400 Hz (user-adjustable)
A.1 Power Ratings
4A0414
4A0515
300
350
400-450
346
410
465
<3>
±5%
316
375
425
276
316
392
362
414
515
User-adjustable between 1 and 5
<5>
<5>
kHz
4A0675
500-550
657
601
514
675
A