Table A.15 Sizing Method A, 480 V Single-Phase Input (-5% to +10%), 460 V Three-Phase Motor
Without Additional Impedance
Drive
Output Capacity
Model
Motor
Motor
Power
FLA
(HP)
4A0002
0.33
0.76
4A0004
0.75
1.6
4A0005
1
2.1
4A0007
1
2.1
4A0009
2
3.4
4A0011
2
3.4
4A0018
2
3.4
4A0023
3
4.8
4A0031
5
7.6
4A0038
7.5
11
4A0044
7.5
11
4A0058
10
14
4A0072
15
21
4A0088
15
21
4A0103
15
21
4A0139
30
40
4A0165
30
40
4A0208
50
65
4A0250
60
77
4A0296
60
77
4A0362
75
96
4A0414
100
124
4A0515
100
124
4A0675
125
156
Table A.16 Sizing Method A, 480 V Single-Phase Input (-5% to +10%), 400 V Three-Phase Motor
Without Additional Impedance
Drive
Output Capacity
Model
Motor
Motor
Power
FLA
(HP)
4A0002
0.33
0.88
4A0004
0.75
1.8
4A0005
1
2.4
4A0007
1
2.4
4A0009
2
3.9
4A0011
2
3.9
4A0018
2
3.9
4A0023
3
5.5
4A0031
5
8.7
4A0038
7.5
12.7
4A0044
7.5
12.7
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
Single Phase
Input Load
Power
Current (A)
DC Type
(kVA)
1.1
2.4
URX000041
1.9
4.2
URX000041
2.3
5.1
05P00620-0110
2.5
5.6
05P00652-0213
4.6
10
URX000048
4.6
10
URX000053
4.4
9.7
URX000052
6.3
14
URX000052
10
22
URX000055
14
31
05P00620-0123
14
31
URX000061
14
30
20
43
20
44
20
45
38
84
39
85
DC Link Choke
62
136
74
162
75
165
93
205
122
267
125
275
157
345
Single Phase
Input Load
Power
Current (A)
DC Type
(kVA)
1.1
2.4
URX000041
1.9
4.2
URX000041
2.3
5.1
05P00620-0110
2.5
5.6
05P00652-0213
4.6
10
URX000048
4.6
10
URX000053
4.4
9.7
URX000052
6.3
14
URX000052
10
22
URX000055
14
31
05P00620-0123
14
31
URX000061
With Additional Impedance
(use either DC type or AC type)
Yaskawa Reactor Part
Output Capacity
Number
AC Type
URX000295
URX000299
URX000303
URX000308
URX000312
URX000316
URX000316
URX000316
URX000324
URX000327
URX000327
URX000332
Do Not Use AC
Reactor
URX000335
URX000341
URX000341
URX000347
Built-in
URX000347
URX000350
URX000353
URX000356
URX000353
Do Not Use
With Additional Impedance
(use either DC type or AC type)
Yaskawa Reactor Part
Output Capacity
Number
AC Type
URX000295
URX000299
URX000303
URX000308
URX000312
URX000316
URX000316
URX000316
URX000324
URX000327
URX000327
A.4 Drive Derating Data
Single Phase
Input Load
Motor
Motor
Power
Power
FLA
(kVA)
(HP)
0.5
1.1
0.98
1
2.1
1.7
1.5
3
2.5
2
3.4
3
3
4.8
4.3
3
4.8
4.7
3
4.8
4.6
5
7.6
7
7.5
11
9.9
10
14
14
10
14
13
15
21
19
15
21
20
15
21
20
20
27
25
30
40
36
30
40
37
50
65
59
60
77
70
75
96
87
100
124
115
125
156
143
100
124
116
125
156
157
Single Phase
Input Load
Motor
Motor
Power
Power
FLA
(kVA)
(HP)
0.5
1.26
0.98
1
2.4
1.7
1.5
3.4
2.5
2
3.9
3
3
5.5
4.3
3
5.5
4.7
3
5.5
4.6
5
8.7
7
7.5
12.7
9.9
10
16
14
10
16
13
Current (A)
2.1
3.8
5.5
6.7
9.5
10
10
15
22
31
28
41
43
44
54
80
81
130
154
192
251
314
255
345
Current (A)
2.1
3.8
5.5
6.7
9.5
10
10
15
22
31
28
A