B.7 H Parameters: Multi-Function Terminals

B.7 H Parameters: Multi-Function Terminals
H parameters assign functions to the multi-function input and output terminals.
u

H1: Multi-Function Digital Inputs

No.
(Addr.
Name
Hex)
Multi-Function Digital
H1-01
Input Terminal S1
(0438)
Function Selection
Multi-Function Digital
H1-02
Input Terminal S2
(0439)
Function Selection
Multi-Function Digital
H1-03
Input Terminal S3
(0400)
Function Selection
Multi-Function Digital
H1-04
Input Terminal S4
(0401)
Function Selection
Multi-Function Digital
H1-05
Input Terminal S5
(0402)
Function Selection
Multi-Function Digital
H1-06
Input Terminal S6
(0403)
Function Selection
Multi-Function Digital
H1-07
Input Terminal S7
(0404)
Function Selection
H1-08
Multi-Function Digital
(0405)
Input Terminal S8
Function Selection
H1-21
(02D7) External Fault 1 Delay
Time
H1-22
(02D8) External Fault 2 Delay
Time
H1-23
(02D9) External Fault 3 Delay
Time
H1-24
(02DA) External Fault 4 Delay
Time
H1-25
(02DB) External Fault 5 Delay
Time
H1-26
(02DC) External Fault 6 Delay
Time
H1-27
(02DD) External Fault 7 Delay
Time
276
LCD Display
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S1 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S2 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S3 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S4 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S5 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S6 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S7 Func Sel
Note:
Assigns a function to the multi-function digital inputs.
Refer to pages
Term S8 Func Sel
Note:
Sets the amount of time delay applied to the EF1 fault.
EF1 Delay Time
(20 ≤ H1-01 ≤ 2F)
Sets the amount of time delay applied to the EF2 fault.
EF2 Delay Time
(20 ≤ H1-02 ≤ 2F)
Sets the amount of time delay applied to the EF3 fault.
EF3 Delay Time
(20 ≤ H1-03 ≤ 2F)
Sets the amount of time delay applied to the EF4 fault.
EF4 Delay Time
(20 ≤ H1-04 ≤ 2F)
Sets the amount of time delay applied to the EF5 fault.
EF5 Delay Time
(20 ≤ H1-05 ≤ 2F)
Sets the amount of time delay applied to the EF6 fault.
EF6 Delay Time
(20 ≤ H1-06 ≤ 2F)
Sets the amount of time delay applied to the EF7 fault.
EF7 Delay Time
(20 ≤ H1-07 ≤ 2F)
Description
158
to
159
for descriptions of setting values.
Set unused terminals to F.
158
to
159
for descriptions of setting values.
Set unused terminals to F.
158
to
159
for descriptions of setting values.
Set unused terminals to F.
158
to
159
for descriptions of setting values.
Set unused terminals to F.
158
to
159
for descriptions of setting values.
Set unused terminals to F.
158
to
159
for descriptions of setting values.
Set unused terminals to F.
158
to
159
for descriptions of setting values.
Set unused terminals to F.
158
to
159
for descriptions of setting values.
Set unused terminals to F.
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
Values
Page
Default: 40 (F)
<1>
158
Min.: 1
Max.: 9F
Default: F
Min.: 1
158
Max.: 9F
Default: 26
Min.: 0
158
Max.: 9F
Default: 14
Min.: 0
158
Max.: 9F
Default: 8D (0)
<1>
158
Min.: 0
Max.: 9F
Default: 80 (3)
<1>
158
Min.: 0
Max.: 9F
Default: 81 (4)
<1>
158
Min.: 0
Max.: 9F
<1>
Default: F (6)
158
Min.: 0
Max.: 9F
Default: 0.00 s
Min.: 0.00
Max.: 300.00
Default: 0.00 s
Min.: 0.00
Max.: 300.00
Default: 0.00 s
Min.: 0.00
Max.: 300.00
Default: 0.00 s
Min.: 0.00
Max.: 300.00
Default: 0.00 s
Min.: 0.00
Max.: 300.00
Default: 0.00 s
Min.: 0.00
Max.: 300.00
Default: 0.00 s
Min.: 0.00
Max.: 300.00