P5: Pump Hand Mode - YASKAWA iQpump1000 Quick Start Manual

Ac drive
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

B.11 P: Pump Parameters
No.
(Addr.
Name
Hex)
P4-13
(0D06) Thrust Bearing
Deceleration Time
P4-17
(0D0A) Utility Start Delay
P4-21
Low City Input Select
(0D0E)
P4-22
(0D0F) Low City On-Delay
Time
P4-23
(0D10) Low City Off-Delay
Time
P4-24
(0D11) Low City Alarm Text
P4-25
Remote Drive Disable
(0D12)
Selection
P4-26
(0D13) Remote Drive Disable
On-Delay
P4-27
(0D14) Remote Drive Disable
Off-Delay
P4-31
(0D18) Lube Pump Delay
Timer
<1> Unit is determined by P1-02, Ssytem Units, setting.
<2> Unit text is set by P1-18, Prime Loss Detection Method.
u

P5: Pump HAND Mode

No.
(Addr.
Name
Hex)
P5-01
(0D2C) HAND Mode Ref
Source
P5-02
(0D2D) HAND Reference 1
308
LCD Display
Sets the amount of time it takes to bring the drive from the Thrust
Frequency set in P4-12 to stop when Thrust Mode is active.
When the Run command is removed while the drive is operating
Thrust Dec Time
in Thrust Mode above the Thrust Frequency, the time set in this
parameter is used when the frequency reference is at or below
the thrust frequency.
Sets the amount of time that the drive will delay starting if a Run
command is present at power-up.
When P1-01, Pump Mode, is set to 3 (MEMOBUS network),
Utility Delay
the drive is unavailable to the network (Pump Off Network)
when the function is active.
Setting this parameter to 0.0 disables the function.
Selects the type of pressure switch connected to the "Low City
Press" digital input (H1-0o = 73).
Low City In Sel
0: Normally open (closed indicates the Low City Pressure
0: Normally Open
condition)
1: Normally Closed
1: Normally closed (open indicates the Low City Pressure
condition)
Sets the amount of time a Low City Pressure condition needs to
be present before the drive will stop.
Low City On Dly
Sets the amount of time a Low City Pressure condition needs to
be absent before the drive will restart.
Low City Off Dly
Selects the alarm message that will be displayed when a Low
Low City Alarm Txt
City Pressure condition is detected.
0: Low Cty Pressure
0: Low city pressure
1: Low Suction Pres
1: Low suction pressure
2: Low Watr in Tank
2: Low water in tank
Selects the type of pressure switch connected to the "Remote
Drive Disable" digital input (H1-0o = 95).
Rem Drv Dis Sel
0: Normally open (closed indicates the Remote Drive Disable
0: Normally Open
condition)
1: Normally Closed
1: Normally closed (open indicates the Remote Drive Disable
condition)
Sets the amount of time a Remote Drive Disable condition must
be present before the drive will stop.
Drv Dis On-Delay
Sets the amount of time a Remote Drive Disable condition must
be absent before the drive will run.
Drv Dis OffDelay
Sets the amount of time to delay the drive output and to energize
the Lube Pump digital output (H2-oo = 8B) before the drive
Lube Pump Time
is allowed to run.
Setting this parameter to 0.0 disables the function.
LCD Display
Sets the HAND Mode reference.
Hand Mode Ref.
0: Analog input A1 (0-10 V)
0: Analog Input
1: P5-02 (HAND reference)
1: Hand Ref 1 (OPR)
Sets the frequency reference used when HAND Mode is active
and P5-01 is set to 1.
HAND Reference 1
Description
Description
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
Values
Page
Default: 5.0 s
Min.: 0.0
Max.: 600.0
Default: 0.2 min
Min.: 0.0
168
Max.: 1000.0
Default: 1
Range: 0, 1
Default: 10 s
Min.: 1
Max.: 1000
Default: 5 s
Min.: 0
Max.: 1000
Default: 0
Range: 0 to 2
Default: 1
Range: 0, 1
Default: 0 s
Min.: 0
Max.: 1000
Default: 0 s
Min.: 0
Max.: 1000
Default: 0.0 s
Min.: 0.0
Max.: 300.0
Values
Page
Default: 1
Range: 0, 1
Default: 40.0 Hz
Min.: 0
169
Max.: [E1-04]