YASKAWA iQpump1000 Quick Start Manual page 91

Ac drive
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

Drive Model
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
<1>
–, +1
4A0139
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
<1>
–,+1
4A0165
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
<1>
–,+1
4A0208
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
<1>
–,+1
4A0250
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
–,+1
<1>
4A0296
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
–,+1
<1>
4A0362
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
<1> <2>
–,+1
4A0414
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
<1> <2>
–,+1
4A0515
+3
R/L1, S/L2, T/L3
U/T1, V/T2, W/T3
<1> <2>
–,+1
4A0675
+3
<1> Drive models 4A0058 to 4A0675 require the use of UL-Listed closed-loop crimp terminals for UL/cUL compliance. Use only the tools recommended
by the terminal manufacturer for crimping.
<2> When installing an EMC filter, additional measures must be taken to comply with IEC61800-5-1.
for details.
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
Recomm. Gauge
Terminal
AWG, kcmil
Wire Range
AWG, kcmil
3/0
1/0 to 4/0
2/0
1/0 to 4/0
1/0 to 4/0
3 to 4/0
4
4
4/0
3/0 to 4/0
4/0
3/0 to 4/0
1 to 4/0
1/0 to 4/0
4
4 to 2
300
2 to 300
300
2 to 300
1 to 250
3 to 3/0
4
4 to 300
400
1 to 600
400
1/0 to 600
3/0 to 600
1 to 325
2
2 to 350
500
2/0 to 600
500
2/0 to 600
3/0 to 600
1 to 325
2
2 to 350
4/0 × 2P
3/0 to 600
4/0 × 2P
3/0 to 600
4/0 to 600
3/0 to 600
1
1 to 350
300 × 2P
4/0 to 300
300 × 2P
4/0 to 300
3/0 to 300
3/0 to 300
1
1 to 3/0
3/0 × 4P
3/0 to 300
4/0 × 4P
3/0 to 300
1/0 to 300
1/0 to 300
1/0
1/0 to 300
300 × 4P
4/0 to 300
300 × 4P
4/0 to 300
1/0 to 300
1/0 to 300
2/0
2/0 to 300
3.6 Main Circuit Wiring
Screw
Tightening Torque
Size
N·m (lb.in.)
18 to 23
M10
(159 to 204)
18 to 23
M10
(159 to 204)
18 to 23
M10
(159 to 204)
18 to 23
M10
(159 to 204)
32 to 40
M12
(283 to 354)
18 to 23
M10
(159 to 204)
32 to 40
M12
(283 to 354)
32 to 40
M12
(283 to 354)
18 to 23
M10
(159 to 204)
32 to 40
M12
(283 to 354)
32 to 40
M12
(283 to 354)
32 to 40
M12
(283 to 354)
32 to 40
M12
(283 to 354)
Refer to EMC Filter Installation on page 338
3
91

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents