Single-Phase Input Sizing Method B (86% Maximum Power of Connected Motor Size)
Use single-phase input Sizing Method B for applications requiring a maximum of 86% motor power, such as a fully loaded
fan or pump that does not draw full power from motor or a fan or pump that is never run at full load.
There is no overload capacity for Sizing Method B.
Table A.18 Sizing Method B, 240 V Single-Phase Input (230 V to 240 V), 230 V Three-Phase Motor
Drive Model
2A0004
2A0006
2A0008
2A0010
2A0012
2A0018
2A0021
2A0030
2A0040
2A0056
2A0069
2A0081
2A0110
2A0138
2A0169
2A0211
2A0250
2A0312
2A0360
2A0415
Table A.19 Sizing Method B, 480 V Single-Phase Input (460 V to 480 V), 460 V Three-Phase Motor
Drive Model
4A0002
4A0004
4A0005
4A0007
4A0009
4A0011
4A0018
4A0023
4A0031
4A0038
4A0044
4A0058
4A0072
4A0088
4A0103
4A0139
4A0165
4A0208
4A0250
4A0296
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
Output Capacity
Motor Power (HP)
0.5
1
1
1.5
2
3
3
4
4
7.5
10
15
15
20
25
30
40
50
60
75
Output Capacity
Motor Power (HP)
0.3
1
1.5
2
3
3
5
5
10
10
15
20
25
25
25
50
50
60
75
100
Motor FLA
Power (kVA)
2.2
0.989
4.2
1.68
4.2
1.75
6
2.44
6.8
3.20
9.6
4.83
9.6
4.83
15.2
7.82
15.2
7.82
22
11.0
28
14.7
42
21.2
42
18.4
54
23.9
68
29.9
80
35.4
104
46.5
130
57.3
154
68.5
192
84.2
Motor FLA
Power (kVA)
0.76
0.96
2.1
1.98
3
2.85
3.4
3.59
4.8
5.15
4.8
5.15
7.6
8.33
7.6
8.33
14
16.1
14
16.1
21
22.6
27
23.9
34
30.4
34
30.4
34
30.8
65
58.0
65
58.9
77
70.4
96
86.5
124
A.4 Drive Derating Data
Single Phase Input Load
Current (A)
4.30
7.30
7.60
10.6
13.9
21.0
21.0
34.0
34.0
48.0
64.0
92.0
80.0
104
130
154
202
249
298
366
Single Phase Input Load
Current (A)
2.10
4.30
6.20
7.80
11.2
11.2
18.1
18.1
35.0
35.0
49.2
52.0
66.0
66.0
67.0
126
128
153
188
114
248
A