No.
(Addr.
Name
Hex)
U1-12
Drive Status
(004B)
U1-13
Terminal A1 Input
(004E)
Level
U1-14
Terminal A2 Input
(004F)
Level
U1-15
Terminal A3 Input
(0050)
Level
U1-16
Output Frequency after
(0053)
Soft Starter
U1-18
oPE Fault Parameter
(0061)
U1-19
MEMOBUS/Modbus
(0066)
Error Code
U1-24
Input Pulse Monitor
(007D)
U1-25
Software Number
(004D)
(Flash)
U1-26
Software No. (ROM)
(005B)
U1-75
Time-Hour/Minute
(0851)
U1-76
Date – Year
(0852)
U1-77
Date – Month/Day
(0853)
U1-78
Date – Week Day
(0854)
U1-80
Geothermal
(0B9B)
Temperature Input
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
LCD Display
Verifies the drive operation status.
U1 - 12=
Int Ctl Sts 1
Displays the signal level to analog input terminal A1.
Term A1 Level
Displays the signal level to analog input terminal A2.
Term A2 Level
Displays the signal level to analog input terminal A3.
Term A3 Level
Displays output frequency with ramp time and S-curves. Units
SFS Output
determined by o1-03.
Displays the parameter number that caused the oPE02 operation
OPE Error Code
error.
Displays the contents of a MEMOBUS/Modbus error.
U1 - 19=
Transmit Err
Displays the frequency to pulse train input terminal RP.
Term RP Inp Freq
FLASH ID
CPU 1 SW Number
ROM ID
CPU 2 SW Number
Time Hr Min HHMM Displays the current time (Hours and Minutes).
Displays the current year.
Date Year
Date Mo Day MMDD Displays the current date (Month and Date).
Displays the current day of the week.
0: Sunday
1: Monday
2: Tuesday
Date Week
3: Wednesday
4: Thursday
5: Friday
6: Saturday
Displays the geothermal temperature input after the gain and
bias have been applied. This temperature is used by the
Geothermal Temp
Geothermal Function to determine the proper frequency at
which to run the drive.
This monitor is internally limited to -999.9 °F to +999.9 °F.
Description
00000000
1
During run
1
During zero-speed
1
During REV
1
During fault reset
signal input
1
During speed agree
1
Drive ready
1
During alarm
detection
1
During fault detection
00000000
1
CRC Error
1
Data Length Error
0
Not Used
1
Parity Error
1
Overrun Error
1
Framing Error
1
Timed Out
0
Not Used
B.15 U: Monitors
Analog
Unit
Output Level
No signal output
available
10 V: 100%
0.1%
10 V: 100%
0.1%
10 V: 100%
0.1%
10 V: Max
0.01 Hz
frequency
No signal output
available
No signal output
available
Determined by
1 Hz
H6-02
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
available
No signal output
0.1 °F
available
B