L3: Stall Prevention - YASKAWA iQpump1000 Quick Start Manual

Ac drive
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

B.8 L: Protection Function
No.
(Addr.
Name
Hex)
Momentary Power Loss
L2-04
Voltage Recovery
(0488)
Ramp Time
L2-05
Undervoltage Detection
(0489)
Level (Uv1)
L2-06
KEB Deceleration
(048A)
Time
L2-07
KEB Acceleration
(048B)
Time
L2-08
Frequency Gain at KEB
(048C)
Start
L2-10
KEB Detection Time
(048E)
(Minimum KEB Time)
L2-11
DC Bus Voltage
(0461)
Setpoint during KEB
L2-29
KEB Method Selection
(0475)
<1> Default setting is dependent on parameter o2-04, Drive Model Selection.
<2> Default setting is dependent on parameter E1-01, Input voltage Setting.
<3> Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives.
<4> Setting range value is dependent on parameter C1-10, Accel/Decel Time Setting Units. When C1-10 = 0 (units of 0.01 seconds), the setting range
becomes 0.00 to 600.00 seconds.
<5> Values shown are specific to 200 V class drives. Double the value for 400 V class drives. Multiply the value by 2.875 for 600 V class drives, but
set the value below 1040 Vdc (overvoltage protection level).
u

L3: Stall Prevention

No.
(Addr.
Name
Hex)
Stall Prevention
L3-01
Selection during
(048F)
Acceleration
L3-02
Stall Prevention Level
(0490)
during Acceleration
L3-03
Stall Prevention Limit
(0491)
during Acceleration
290
LCD Display
Sets the time for the output voltage to return to the preset V/f
pattern during Speed Search.
PwrL V/F Ramp t
Sets the DC bus undervoltage trip level.
PUV Det Level
Sets the time required to decelerate from the speed when KEB
was activated to zero speed.
KEB Decel Time
Sets the time to accelerate to the frequency reference when
momentary power loss is over. If set to 0.0, the active
KEB Accel Time
acceleration time is used.
Sets the percentage of output frequency reduction at the
beginning of deceleration when the KEB Ride-Thru function is
KEB Freq Red
started.
Reduction = (slip frequency before KEB) × L2-08 × 2
Sets the time to perform KEB Ride-Thru.
KEB Detect Time
Sets the desired value of the DC bus voltage during KEB Ride-
Thru.
KEB DC Bus Level
KEB Mode Sel
0: Single Drive KEB Ride-Thru 1
0: Single Mode KEB1
1: Single Drive KEB Ride-Thru 2
1: Single Mode KEB2
2: System KEB Ride-Thru 1
2: System Mode
3: System KEB Ride-Thru 2
KEB1
3: System Mode
KEB2
LCD Display
0: Disabled.
StallP Accel Sel
1: General purpose. Acceleration is paused as long as the current
0: Disabled
is above the L3-02 setting.
1: General purpose
2: Intelligent. Accelerate in the shortest possible time without
2: Intelligent
exceeding the L3-02 level.
Used when L3-01 = 1 or 2. 100% is equal to the drive rated
current.
StallP Accel Lvl
Sets Stall Prevention lower limit during acceleration when
StallPAcc LowLim
operating in the constant power range. Set as a percentage of
drive rated current.
Description
Description
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
Values
Page
<1>
Default:
Min.: 0.0 s
Max.: 5.0 s
Default: 190
<2> <3>
Vdc
Min.: 150 Vdc
Max.: 210 Vdc
<3>
Default: 0.00 s
Min.: 0.00
<4>
Max.: 6000.0
Default: 0.00 s
Min.: 0.00
<4>
Max.: 6000.0
Default: 100%
Min.: 0
Max.: 300
Default: 50 ms
Min.: 0
Max.: 2000
<2>
Default:
[E1-01] × 1.22
Min.: 150 Vdc
Max.: 400 Vdc
<5>
Default: 0
Range: 0 to 3
Values
Page
Default: 1
Range: 0 to 2
<1>
Default:
Min.: 0%
<1>
Max.: 150%
Default: 50%
Min.: 0
Max.: 100