YASKAWA iQpump1000 Quick Start Manual page 261

Ac drive
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

No.
(Addr.
Name
Hex)
b5-11
PID Output Reverse
(01AF)
Selection
b5-12
Feedback Loss 4 to 20
(01B0)
mA Detection Selection
b5-13
Feedback Loss Goto
(01B1)
Frequency
b5-14
(01B2) Feedback Loss of Prime
Level
b5-17
(01B5) PID Accel/Decel Time PID Acc/Dec Time
b5-34
(019F)
PID Output Lower Limit PID Out Low Lim
b5-35
(01A0) PID Input Limit
b5-39
PID Setpoint Display
(01FF)
Digits
Frequency Reference
b5-40
Monitor Content during
(017F)
PID
b5-41
PI Output 2 Unit
(0160)
Selection
b5-42
PI Output 2 Calculation
(0161)
Mode
b5-43
PI Output 2 Monitor
(0162)
Max Upper 4 Digits
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
LCD Display
0: Negative PID output triggers zero limit.
Output Rev Sel
1: Rotation direction reverses with negative PID output.
0: 0 limit
Note:
1: Reverse
Performs a 4 to 20 mA wire break detection on the analog input
Fdbk 4-20mA Det
that is programmed for PID feedback.
0: Disabled
0: Disabled
1: Alarm only
1: Alarm only
2: Fault
2: Fault
3: Run At b5-13
3: Run at b5-13
Sets the speed at which the drive will run if a 4 to 20 mA wire
FdbkLossGotoFreq
break is detected on the PID Feedback and when b5-12 is set to
3 (Run at b5-13).
Detects loss of prime in the pump when a wire break condition
has occurred.
When the measured quantity determined by P1-18 (output
current, kilowatts, or power) drops below this level for the time
FdbkLoss LOP Lvl
set in P1-20 and the output frequency is at the level set in b5-13,
a "Loss of Prime" condition occurs.
The drive responds to the "Loss of Prime" condition depending
on the setting of P1-22, Loss of Prime Selection.
Sets the acceleration and deceleration time to PID setpoint.
Sets the minimum output possible from the PID controller as a
percentage of the maximum output frequency.
Limits the PID control input (deviation signal) as a percentage
of the maximum output frequency. Acts as a bipolar limit.
PID Input Limit
PID UsrDspDigits
0: No decimal places
0: No Dec (XXXXX)
1: One decimal place
1: 1 Dec (XXXX.X)
2: Two decimal places
2: 2 Dec (XXX.XX)
3: Three decimal places
3: 3 Dec (XX.XXX)
0: Display the frequency reference (U1-01) after PID
Fref Mon Sel@PID
compensation has been added.
0: Fref Mon w PID
1: Display the frequency reference (U1-01) before PID
1: Fref Mon w/o PID
compensation has been added.
PI Out2 Unit Sel
0: No Unit
0: No Unit
1: Pounds per square inch
1: PSI :lb/SqrInch
2: Pascals
2: Pa:Pascals
3: Bar
3: Bar:Bar
4: Inch of Water
4: "WC: InchOfWater
5: Inch of Mercury
5: "Hg:Inch Mercury
6: Feet
6: ft: feet
7: Meters
7: m: meters
8: Degrees Fahrenheit
8: °F:DegFarenheit
9: Degrees Celsius
9: °C:DegCelsius
10: Percent
10: %: Percent
25: Flow (use P6-04)
25: Flow (use P6-04)
0: Linear - the monitor displays PID output
PI Out2 Calc Mode
1: Square root - the monitor displays square root PID output
0: Linear
2: Quadratic - the monitor displays 1/(PID output)
1: Square root
3: Cubic - the monitor displays 1/(PID output)
2: 1/f2
3: 1/f3
Note:
Sets the upper 4 digits of the maximum monitor value.
Used with b5-44 to set maximum monitor value of U5-14 and
PI Out2 MonMax U
U5-15 at maximum frequency.
Note:
Description
When using setting 1, make sure reverse
operation is permitted by b1-04.
3
Used for U5-14 and U5-15 only.
Used for U5-14 and U5-15 only.
B.2 b: Application
Values
Default: 0
Range: 0, 1
Default: 2
Range: 0 to 3
Default: 0.0 Hz
Min.: 0.0
Max.: 400.0
Default: 0.0 A
<1>
Min.: 0.0
Max.: 1000.0
Default: 0.0 s
Min.: 0.0
Max.: 6000.0
Default: 0.00%
Min.: -100.00
Max.: 100.00
Default:
1000.0%
Min.: 0.0
Max.: 1000.0
Default: 1
Range: 0 to 3
Default: 0
Range: 0, 1
Default: 0
Range: 0 to 10;
25
Default: 0
2
Range: 0 to 3
Default: 0
Min.: 0
Max.: 9999
Page
B
261