YASKAWA iQpump1000 Quick Start Manual page 159

Ac drive
Hide thumbs Also See for iQpump1000:
Table of Contents

Advertisement

Setting
External Speed Search
61
command 1
External Speed Search
62
command 2
63
Field weakening
65
KEB Ride-Thru 1 (N.C.)
66
KEB Ride-Thru 1 (N.O.)
67
Communications test mode
68
High Slip Braking (HSB)
6A
Drive enable
73
Low City Press
75
Up 2 command
76
Down 2 command
7A
KEB Ride-Thru 2 (N.C.)
7B
KEB Ride-Thru 2 (N.O.)
80
HAND Mode
81
HAND Mode 2
88
Volute-Thermostat Normally Open
n
H2-01 to H2-03: Terminal M1-M2, M3-M4, and MD-ME-MF Function Selection
The drive has three multi-function output terminals.
H2-02, and H2-03.
No.
H2-01
Terminal M1-M2 Function Selection (relay)
H2-02
Terminal M3-M4 Function Selection (relay)
H2-03
Terminal MD-ME-MF Function Selection (relay)
Setting
0
During run
1
Zero speed
2
Speed agree 1
3
User-set speed agree 1
4
Frequency detection 1
5
Frequency detection 2
6
Drive ready
7
DC bus undervoltage
8
During baseblock (N.O.)
9
Frequency reference source
A
Run command source
B
Torque detection 1 (N.O.)
C
Frequency reference loss
D
Braking resistor fault
E
Fault
F
Through mode
10
Minor fault
11
Fault reset command active
12
Timer output
13
Speed agree 2
14
User-set speed agree 2
15
Frequency detection 3
16
Frequency detection 4
YASKAWA TOEP YAIP1W 01A YASKAWA AC Drive - iQpump1000 Quick Start Guide
Function
Table 4.21
Parameter Name
Table 4.21 Multi-Function Digital Output Terminal Settings
Function
4.6 Basic iQpump Setup and Application Preset Parameters
Page
Setting
89
Volute-Thermostat Normally Closed
8C
Disable Pre-Charge
8D
Multi Setpoint 1
8E
Multi Setpoint 2
8F
Low Water Level
90
High Water Level
92
Reset Accum
95
Remove Drive Disable
A8
Secondary PI Disable (N.O.)
A9
Secondary PI Disable (N.C.)
AA
Secondary PI Inverse Operation
AB
Secondary PI Integral Reset
AC
Secondary PI Integral Hold
AD
Select Secondary PI Parameters
AF
Emergency Override Forward Run
B0
Emergency Override Reverse Run
lists the functions available for theses terminals using H2-01,
Page
Setting
17
Torque detection 1 (N.C.)
18
Torque detection 2 (N.O.)
19
Torque detection 2 (N.C.)
1A
During reverse
1B
During baseblock (N.C.)
1E
Restart enabled
1F
Motor overload alarm (oL1)
20
Drive overheat pre-alarm (oH)
22
Mechanical weakening detection
2F
Maintenance period
30
During torque limit
37
During frequency output
38
Drive enabled
39
Watt hour pulse output
3C
LOCAL/REMOTE status
3D
During speed search
3E
PID feedback low
3F
PID feedback high
4A
During KEB Ride-Thru
4C
During fast stop
4D
oH Pre-alarm time limit
4E
Braking transistor fault (rr)
4F
Braking resistor overheat (oH)
Function
Setting Range
0 to 192
37: During Frequency Output
0 to 192
F: Through Mode
0 to 192
Function
Page
Default
E: Fault
Page
4
159

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents