X2 Remote Input Signal Pins - Edwards STP-iS2207 Series Instruction Manual

Turbomolecular pump
Table of Contents

Advertisement

4
(1)
COM
(1)
COM
(1)
COM
(1)
MT-89E-001-C
Page 58
STP-iS2207 Series Turbomolecular Pump
Pin
Pins for inputting the START signal.
(2)
Short the circuits between (1)-(2).
When the pins (1)-(2) are opened, the STP pump will stop.
START IN
Pins for inputting the RESET signal.
(15)
When a safety function operates, remove the cause of the
abnormality/error after confirming the STP pump has stopped.
When the cause of the abnormality/error is removed, short the
RESET IN
circuits between (1)-(15) for 0.3 seconds or more to reset the
failure signal (The "FAILURE" LED extinguishes).
Pins for second speed signal input.
(3)
When using this function, set "ENABLE" by the serial
communication or the STP-Link.
When pins (1)-(3) are set to close, rotational speed will be
SECON
second speed when pump state is NORMAL.
SPEED IN
When pins (1)-(3) are set to open, rotational speed will be
normal speed when pump state is NORMAL.
When using the second speed function to switch the rotational
speed through the serial communication port or STP-Link, open
the circuits between (1)-(3).
Pins for option signal input. (Not used)
(14)
OPT IN
Table 12 - X2 REMOTE input signal pins
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Stp seriesStp-is2207Stp-is2207c