D. HYDRAULIC OIL LEVEL
a. For M105: Turn filler cap counterclockwise to
loosen bung, and remove dipstick.
M205, M155
b. For M205, M155: Turn filler cap counte rclockwise
to unlock cap, and remove dipstick.
c. Check that l evel is b etween LOW and FULL
marks.
d. Re-install dipstick, and turn clo ckwise to
tighten/lock.
Form 169242
PRE-DELIVERY CHECKS
M105
E. FUEL SEPARATOR
a. Place a container under the filter drain.
b. Turn drain v alve by ha nd 1-1/2 to
counterclockwise, until draining occurs.
c. Drain the filter sump of water and sediment, until
clear fuel is visible. Clean as necessary.
d. Turn the valve clockwise to close the drain.
e. Safely dispose of fluid in container.
F. ENGINE COOLANT
a. Check the coolant level in the coolant recovery
tank. Tank should be at least one-half full.
b. Check coolant concentration in the radiator.
Coolant shall be rated for temperatures of -30°F
(-34°C).
105
2 turns
Revision F