YASKAWA XtraDrive Series User Manual page 67

Ac servo driver
Table of Contents

Advertisement

Module
Name
Pn50B.2: /P-CL Input
Pn50B.3: /N-CL Input
Pn50C.0: /SPD-D Input
Pn50C.1: /SPD-A Input
Pn50C.2: /SPD-B Input
Pn50C.3: /C-SEL Input
Pn50D.0: /ZCLAMP Input
Pn50D.1: /INHIBIT Input
AUDIN - 7 bis rue de Tinqueux - 51100 Reims - France
Web : http: www.audin.fr - Email : info@audin.fr
/P-CL Signal Mapping (External Forward
Torque Limit Enable according to
Pn404):
Refer to Pn50A.1, page 54.
/N-CL Signal Mapping (External
Reversed Torque Limit Enable:
Refer to Pn50A.1, page 54.
/SPD-D Signal Mapping
Internal Speed Selection — Selects
direction (0 — Forward; 1 — Reversed)
Refer to Pn50A.1, page 54.
/SPD-A Signal Mapping
Internal Speed Selection — Defines
internal speed together with /SPD-B
Refer to Pn50A.1, page 54.
/SPD-B Signal Mapping.
Internal Speed Selection — Defines
internal speed together with /SPD-A
Refer to Pn50A.1, page 54.
/C-SEL Signal Mapping (Control Mode
Switching):
Refer to Pn50A.1, page 54.
/ZCLAMP Signal Mapping (Zero
Clamping):
Refer to Pn50A.1, page 54.
/INHIBIT Signal Mapping (Disabling
Pulse-Train Input):
Refer to Pn50A.1, page 54.
Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20
XtraDrive-DP Parameters List
A
PPENDIX
Description
55
B

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xtradrive-dp

Table of Contents