Configuration Of The Lucent Technologies Data Switch Lcs60 - HP LCS60 Installation Manual

Network interface for ethernet r3.0
Table of Contents

Advertisement

Remove the rubber caps from the optical fiber cable that runs from the
receiver side of the LCS60, and connect the optical fiber cable to the
transmitter side (bottom connector) of the CPM-HS module in the data
switch.
5 . Set the MODE toggle switch on the CPM-HS faceplate to ENABLE.
6 . Set the Loopback switch on the CPM-HS paddleboard to NORM.
Note:
If the cable is installed backwards, no harm will be done when powering
up.
Configuration of the Lucent Technologies Data Switch
– LCS60
Configuration of the CPM-HS module in the data switch is done in the same way
as a CPM-HS module connected to a UNIX System host. The number of chan-
nels should be the same as the number of channels with which the LCS60 is con-
figured, 512.
The first local address entered must match the first IP Network Security Group's
name. Subsequent local addresses should match the other IP Security Group
names entered into the LCS60 configuration database. The LCS60 supports up to
four IP Network Security Groups. The first local address should be the same as
the node name of the LCS60. Additional information on creating the local
address group, and CPM-HS entries can be found in the Lucent Technologies
data switch documentation.
After the CPM-HS module is plugged into the data switch, the CPM-HS module
must be configured from the data switch console. The Network Administrator
enters the group name and local address for the LCS60, and configures the
CPM-HS module. The following tasks are performed at the data switch console:
Enter group name
Define the local address for the LCS60
Configure the CPM-HS module.
Sample dialogues (see also Figure 3-1) for these tasks are described below.
Issue 3
Installing the LCS60