HP LCS60 Installation Manual page 252

Network interface for ethernet r3.0
Table of Contents

Advertisement

Remote Upgrade
7 . On the server, select item 6 to transfer the software generic from the server
to the client. Before the copy is initiated, the client is checked to ensure it
has sufficient disk space to receive and store the copy. The software is
downloaded in the client's save area. Do not continue with step 8 until
this transfer has completed.
8 . After the transfer from the server is complete, on the client, select menu
item 2. This will remove the previously installed software generic (and
patch, if a patch is installed) and stop all services and protocols. You must
perform this step before continuing on to step 9.
Note:
After this step has been completed do not quit or exit from the lcsadm
command or you will have to manually complete the process as follows:
From the root login prompt on the client execute the following:
# pkgadd -d /var/spool/pkg
Continue with step 10 below.
9 . On the client, select menu item 3. This will install the downloaded LCS60
software generic. After this step has been completed successfully you may
exit or quit from the lcsadm command.
10 . Reboot the client LCS60 using /etc/shutdown -g0 -y -i6.
11 . On the client, login as root and perform the initsetup procedures as
described in Chapter 3.
12 . On the client, configure all required protocols and services (using the
lcsadm commands) and enter start all from the lcsadm interface's Top
directory.
13 . On the client, select item 4 from the Remote Upgrade Installation Menu to
disable the client from receiving a generic download. Exit lcsadm.
14 . On the server, remove the LCS60 Software Installation tape and store it in
a safe place. Exit lcsadm.
Note:
If the LCS60 software generic is no longer needed, remove it from the
server by selecting item 7 under the SERVER Procedures from the Remote
Upgrade Installation Menu.