ADJ 8.1 Lead Edge Registration Adjustment

Purpose
To measure and adjust lead edge image to paper registration.
Go to the relevant procedure:
3635 Checkout
3550 Checkout
3635 Checkout
NOTE: Both the Check and the Adjustment use an internal test pattern. Both are performed in
diagnostics.
Check the lead edge registration (top edge of portrait A4 or 8.5x11 inch). Perform the following:
1.
Enter
dC606 Internal Print Test Patterns (3635
2.
Select test pattern 7.
3.
Select Features. For simplex lead edge check, select 1 Sided. For duplex lead edge
check select, 2 Sided.
4.
Select the tray. Select Start Test.
NOTE: Simplex copies exit face down. Duplex copies exit side 1 face down (side 2 face
up).
Phaser 3635MFP/WorkCentre 3550
Only).
April 2010
5.
Measure the distance between the lead edge of the paper and the ABC line on the printed
test pattern,
Figure
1.
Figure 1 Test pattern 7
6.
If the distance measured is not 12.7mm (0.5 inch) +/-3mm (1/8 inch), perform the
ment.
Adjustment
1.
Select Exit (on the
dC606 Internal Print Test Patterns (3635
2.
Select Diagnostic Routines.
3.
Select Copier Routines.
4.
Select 131 NVM Read Write.
5.
Refer to
Table
1. Select the relevant NVM setting.
Table 1 NVM location
Mode
Tray
Simplex
1
Simplex
2
Simplex
Bypass
Duplex Side 1
1
4-49
Only).
Location
07-100
07-200
07-500