4.2.5.
Pallet Type
Standard pallet is displayed in pallet type. Choose other pallet out of the list if
needed.
4.3.

Parameters

4.3.1.
Maximum layers
The filed displays the maximum quantity of layers which can be stacked. The value is
automatically calculated, but can be reduced if preferred.
Note: Formula of maximum No. layer
Pallet position height(PP)
Maximum operation range height data (Z max)
Inching rise distance above pallet (D4)
Standby position above pallet height (D2z)
Actual use pallet height (PH)
Qty plt on floor (M)
Product height (H)
Pallet on the floor:
Maximum No. layer = (Zmax - PP - PH * M - ((D4, D2z)max - H)) / H
Pallet on the pallet station:
Maximum No. layer = (Zmax - PP - PH - ((D4, D2z)max - H)) / H
This layer is ranges from 0 to 99 from which it is omitted below the decimal
point. Even if the result becomes 0, it is likely to be able to stack by setting
APR(Special)
4.3.2.
Layer quantity
This field displays the actual if layers that will be stacked. The actual quantity of
layers that will be stacked must be at or below the maximum quantity of layers to be
stacked.
4-6