CAN Trigger and Serial Decode

The steps required for CAN trigger and decode "Setup for CAN Signals", "CAN
Triggering" and "CAN Serial Decode" to trigger and decode the signals.

Setup for CAN Signals

1.
Press the Decode key to enter the DECODE function menu.
2.
Press the Decode softkey and select the desired decoder (Decode1 or Decode2).
3.
Press Protocol softkey and then select CAN by turning Universal Knob.
4.
Press Signal softkey to enter the SIGNAL menu as Figure 52 shows.
5.
Set CAN-H:
a.
Press CAN-H softkey to select the channel that is connected to the CAN-H
signal.
b.
Press first Threshold key to set the CAN-H signal's threshold voltage level
using the Universal Knob. The threshold voltage level is for decoding, and it
will be used as the trigger voltage level when setting the trigger type to serial.
6.
Set CAN-L:
a.
Press CAN-L to select the channel that is connected to the CAN-L signal.
b.
Press second Threshold key to set the CAN-L signal's threshold voltage level
using the Universal Knob. The threshold voltage level is for decoding, and it will
be used as the trigger voltage level when setting the trigger type to serial.
7.
Press the Configure softkey to enter the BUS CONFIG menu.
8. Press Baud to set baud rate using the Universal Knob.
The baud rate can be set at predefined values (from 5kb/s to 1Mb/s) or custom
values (from 5kb/s to 1Mb/s).
If the desired baud rate is not listed, press Baud and select custom option, press
Figure 52 CAN SIGNAL Menu