Index Subindex
0x1F00.01
0x1F00.02
...
0x1F00.04
Output Process Data
Objects 0x160x:
The content of objects 0x1600 to 0x1603 depends on the operating mode settings of the
corresponding ports. Object 0x160x contains the port operating modes "IO-Link" and
"Digital output." The assignment is as follows:
• Object 0x1600 is assigned to port X01.
• Object 0x1601 is assigned to port X02.
• Object 0x1602 is assigned to port X03.
• Object 0x1603 is assigned to port X04.
Objects 0x160x with port operating mode "IO-Link":
The following table describes the assignment of output process data to the port for the
"IO-Link" port operating mode.
Index Subindex
0x7000.01
0x7000.02
...
0x7000.20
0x7010.01
0x7010.02
...
0x7010.20
Product manual | Version: 1.0.0
4PORT IOL-A FLD EC DC 24V 2.0A
Table 25: Object 0x1A80: assignment of the IO-Link port status
Size
Name
1 byte
State of IO-Link port
X01
1 byte
State of IO-Link port
X02
...
...
1 byte
State of IO-Link port
X04
Table 26: Object 0x160x: Assignment of the IO-Link Output Data
Size
Name
1 byte
Output byte 0
1 byte
Output byte 1
...
...
1 byte
Output byte 31
1 byte
Output byte 0
1 byte
Output byte 1
...
...
1 byte
Output byte 31
Description
Bit 0...3 IO-Link status
0: Port inactive
1: SIO mode digital input
2: SIO mode digital output
3: communication OP
4: communication STOP
Bit 4...7 ErrorCode
0: No error
1: Watchdog error
2: Buffer overrun
3: Invalid device ID
4: Invalid manufacturer ID
5: Invalid IO-Link version
6: Invalid "Frame Capability"
7: Invalid cycle time
8: Invalid length: input process data
9: Invalid length: output process data
10: No IO-Link device detected
11: PreOP error
Description
Object 0x1600 with output data of port X01
IO-Link output data of the IO-Link device on
port X01. For a description of the data, see
the manual from the manufacture of the IO-
Link device used.
The number of "Output bytes" corresponds
to the length of the module used in slot "IO-
Link Port X01" and can be 1, 2, 4, 8, 16 or
32 bytes.
Object 0x1601 with output data of port X02
IO-Link output data of the IO-Link device on
port X02. For a description of the data, see
the manual from the manufacture of the IO-
Link device used.