Table 39: "Port Mode" Drop-Down Menu: Selecting the Operating Mode for Pin 4 of the Selected IO-Link Port
Selection Option
Digital input, normally
open
Digital input, normally
closed
Digital Output
Digital output, static on
Setting the Filter Time for Digital Inputs
The filter time for the digital inputs can be selected from the Digital input signal filter
drop-down menu. You can select from the following values:
• No digital input filter
• 3 ms
• 15 ms
• 20 ms
If the No digital input filter option is selected, no filtering occurs.

10.3.1.4.2 Configuring IP Parameters

The EtherCAT
modules, no manual IP address configuration is necessary.
Other tabs under the menu item Settings are described below.
Product manual | Version: 2.0.0
8DIO FLD EC DC 24V 2.0A
Description
The port is used as a digital input. All elements of the port configuration are ig-
nored except for the input and output data length.
The port is used as a digital input. The signals to the port are inverted. All elements
of the port configuration are ignored except for the input and output data length.
The port is used as a digital output. All elements of the port configuration are ig-
nored except for the input and output data length.
The port is used as a digital output. The signal on pin 4 is permanently set to
logic 1.
Figure 17: Settings Menu Item, Device Configuration Tab (Example View)
®