Setting Parameters; Parameterization; Wago Webserver I/O Field; Call Wago Webserver I/O Field - WAGO 765-4203/0100-0000 Product Manual

4-port io-link master class a; ethercat; 24 v dc; 2.0 a; 4 x m12 connection
Table of Contents

Advertisement

765-4203/0100-0000
Slot/Module
IOL_0/4_I/O byte
IOL_0/8_I/O byte
IOL_0/16_I/O byte
IOL_0/32_I/O byte
IOL_1/1_I/O byte
IOL_2/2_I/O byte
IOL_4/4_I/O byte
IOL_8/8_I/O byte
IOL_16/16_I/O byte
IOL_32/32_I/O byte

10.2.1.3 Setting Parameters

You can set the parameters for the module in the configuration software of the EtherCAT
master. The existing parameters contain the basic settings for the module, which you can
adapt to your application. Set the module and port parameters in the start-up parameters
in the configuration software of the EtherCAT
these parameters to the module when communication starts up.
You can find all the module parameters in

10.3 Parameterization

The following tools are described below:

• WAGO Webserver I/O Field

8 WAGO IO-Link Configurator [} 93]
• WAGO I/O Field app
• OPC UA Server
10.3.1 WAGO Webserver I/O Field

10.3.1.1 Call WAGO Webserver I/O Field

This section describes how you can use the integrated software WAGO I/O Field Web-
server to get access to detailed information on the current operating state of the product
and make settings to affect the product's behavior.
ü Requirement: Opening the user interface of WAGO I/O Field Webserver requires that
product's IP address is configured and known.
Proceed as follows:
Enter the following text in the address bar of your Web browser to address the prod-
uct:
http://<IP-address-according-to-configuration>
e.g., http://192.168.10.2.
Product manual | Version: 1.0.0
4PORT IOL-A FLD EC DC 24V 2.0A
Description
IO-Link device with 4 bytes of output process data
IO-Link device with 8 bytes of output process data
IO-Link device with 16 bytes of output process data
IO-Link device with 32 bytes of output process data
IO-Link device with 1 bytes of input process data and 1 bytes of
output process data
IO-Link device with 2 bytes of input process data and 2 bytes of
output process data
IO-Link device with 4 bytes of input process data and 4 bytes of
output process data
IO-Link device with 8 bytes of input process data and 8 bytes of
output process data
IO-Link device with 16 bytes of input process data and 16 bytes of
output process data
IO-Link device with 32 bytes of input process data and 32 bytes of
output process data
®
master. The EtherCAT
8 Module Parameters
Commissioning
®
®
master sends
[} 45].
65