Communication Interfaces; Io-Link (Master); Network Connections; Ethernet Interfaces - WAGO 765-4203/0100-0000 Product Manual

4-port io-link master class a; ethercat; 24 v dc; 2.0 a; 4 x m12 connection
Table of Contents

Advertisement

Properties
Supply Voltage In-
put
M12, L-coded, plug,
5-pin (4 + FE)
Note
Upper limit on current consumption from X32 (Power out)
Before connecting one or more products to the power supply on socket X32 (Power out),
read section
maximum permitted current consumption.

4.2.2 Communication Interfaces

4.2.2.1 IO-Link (Master)

IO-Link (Class A)
M12, A-coded,
socket, 5-pin

4.2.3 Network Connections

4.2.3.1 ETHERNET Interfaces

ETHERNET
M12, D-coded,
socket, 4-pin
16
Product manual | Version: 1.0.0
4PORT IOL-A FLD EC DC 24V 2.0A
Supply Voltage
Pin
Output
1
2
3
4
FE
M12, L-coded,
socket, 5-pin (4 +
FE)
8 Power Supply Examples
Pin
Signal
1
1L+
2
DIO B (DI B/
DQ B)
3
1L–
4
C/Q
DIO A (DI A/
DQ A)
5
n. c.
Pin
Signal
1
TX+
2
RX+
3
TX–
4
RX–
Housing
Shield
Signal
Description
1L+
24 VDC supply voltage U
and sensor/actuator
2L−
Reference potential for 2L
1L−
Reference potential for 1L
2L+
24 VDC auxiliary/control voltage U
FE
Functional ground
[} 42]. There you will find information on the
Description
24 VDC supply voltage U
for sensor/actu-
1L
ator
Digital input/output channel B
Reference potential for 1L+
IO-Link data or
digital input/output channel A
Not connected
Table 6: ETHERNET Interfaces
Description
Positive send data
Positive receive data
Negative send data
Negative receive data
Shield connection; housing is connected to functional
ground
765-4203/0100-0000
Table 4: Supply voltage
for system
1L
2L
Table 5: IO-Link (class A)
Wire Color
Brown
White
Blue
Black
-

Advertisement

Table of Contents
loading

Table of Contents