Commissioning
The Backup Level parameter determines the system behavior when a device connected
to the port is replaced in terms of continued operation with unmodified device parameters.
This parameter can have three different values:
Backup Level
Commissioning
("Disable")
Production
("Backup/Restore")
Production
("Restore")
The Validation and Backup drop-down menu offers the following options for setting the
Inspection Level and Backup Level parameters:
Table 56: Setting the Inspection Levels and Backup Levels for Device Check during Validation and Backup
Selection Option
No device check
Type compatible de-
vice (V1.0)
Type compatible de-
vice (V1.1)
Type compatible de-
vice (V1.1) with
backup + restore
Type compatible de-
vice (V1.1) with re-
store
VendorID Input Field
This element contains the expected manufacturer ID (VendorID, 2 bytes) of the con-
nected device. The permissible values range from 1 to 0xFFFF. This information is re-
quired for the device check for type compatibility. It can be omitted if [No device check]
is selected.
DeviceID Input Field
This element contains the expected device ID (DeviceID, 3 bytes) of the connected de-
vice. The permissible values range from 1 to 0xFFFFFF. This information is required for
the device check for type compatibility. It can be omitted if [No device check] is selected.
PortCycleTime Drop-Down Menu
Depending on the selected operating mode, the expected cycle time of the port either can
be selected from the PortCycleTime drop-down menu or is merely displayed. The en-
coding corresponds to the one in the port status.
76
Product manual | Version: 1.0.0
4PORT IOL-A FLD EC DC 24V 2.0A
Table 55: Possible Values of the Backup Level Parameter
Description
Parameter data of the old device is not saved for transfer to the new device. There-
fore, if the device is replaced, the new device must be parameterized anew.
Changes to all active parameters within the device are copied and saved. Thus all
parameter data of the old device is stored for transfer to a new device.
Device replacement with automatic or semi-automatic data storage is supported.
Changes to all active parameters within the device are not copied and saved. Only
special parameter data of the old device is stored for transfer to a new device.
Device replacement with automatic or semi-automatic data storage is only sup-
ported for these "frozen" parameters.
Inspection Level
Backup Level
NO_CHECK
Disable
TYPE_COMP
Disable
TYPE_COMP
Disable
TYPE_COMP
Backup + Restore
TYPE_COMP
Restore
765-4203/0100-0000
Description
No device check is performed.
Device check for type-compatible device
per IO-Link specification 1.0
Device check for type-compatible device
per IO-Link specification 1.1
Device check for type-compatible device
per IO-Link specification 1.1 with backup &
restore functionality
Device check for type-compatible device
per IO-Link specification 1.1 with restore
functionality