Verify the Rear Chassis Subassembly
6.
Connect the power cords.
See
"Connect Power Cords" on page
7.
Power on the server.
See
"Returning the Server to Operation" on page
Verify the rear chassis subassembly.
8.
See
"Verify the Rear Chassis Subassembly" on page
Related Information
"Remove the Rear Chassis Subassembly" on page 184
■
"Returning the Server to Operation" on page 191
■
Verify the Rear Chassis Subassembly
1.
Ensure that you have completed the following:
Applied power to the server.
■
See
Started the system.
■
See
Log in to Oracle ILOM.
2.
See
"Log In to Oracle ILOM (Service)" on page
3.
Start the faultmagmt shell.
-> start SP/faultmgmt/shell
Are you sure you want to start the faultmgmt shell (y/n)? y
faultmgmtsp>
4.
Use the fmadm faulty command to determine if the server is operating normally.
If a fault was detected, see
■
If no faults were detected, then the rear chassis subassembly has been replaced successfully.
■
No further action is required.