-> set /HOST/diag error_level=max
-> set /HOST/diag hw_change_level=max
Refer to the section on setting the SPARC host keyswitch state in the Oracle ILOM
Administrator's Guide for Configuration and Maintenance Firmware Release 4.0.x for a
description of parameters and values.
View the current values for settings.
4.
Example:
-> show /HOST/diag
/HOST/diag
Targets:
Properties:
error_reset_level = max
error_reset_verbosity = normal
hw_change_level = max
hw_change_verbosity = normal
level = min
mode = normal
power_on_level = max
power_on_verbosity = normal
trigger = hw_change error-reset
verbosity = normal
Commands:
cd
set
show
->
Related Information
"POST Overview" on page 37
■
Clear a Fault Manually
When PSH detects faults, the faults are logged and displayed on the console. In most cases,
after the fault is repaired, the corrected state is detected by the server, and the fault condition
is repaired automatically. However, this repair should be verified. In cases where the fault
condition is not automatically cleared, you must clear the fault manually.
1.
After replacing a faulty FRU, power on the server.
Clear a Fault Manually
Detecting and Managing Faults