2.5 INSTALLATION REQUIREMENTS
Install the plotter in an appropriate place with reference to the following:
Important
• Do not install the plotter in the following places :
On a shaky stand
o
Sloping surfaces
o
Places where vibration of other machines, etc. are transmitted.
o
• Do not stamp on the plotter and do not place heavy things on top of it. The plotter will be
damaged.
• Cover the plotter with a blanket or a cloth like tablecloth and do not close the ventilation hole. If
closing the vent, the plotter could accumulate heat inside and will cause fire.
• Do not install the plotter in a location that has high humidity or is dusty. It could lead to electric
shock and fire.
2.5.1 Environmental conditions for installation
Floor strength of installation place
Power Specifications
Environmental conditions
Notes
• Concerning temperature and humidity, avoid following locations :
Places where temperature or humidity rapidly change, even though within the required conditions.
o
Places that receive direct sunlight, increased illumination or direct air, for example from an air
o
conditioner.
• To keep the temperature and humidity constant, install this product in a location where the air condition
is adjustable.
Power Supply
Frequency Range
Power Capacity
Operative Condition
Guaranteed range of
printing accuracy
Change rate
Archiving environment
31
User's Guide DrafStation and Drafstation Pro
More than 2940 Pa (300 kg/m²)
AC90V – 132V/198V – 264V
50/60Hz ± 1Hz
More than 10 A
Temperature: 10°C to 35°C
Humidity: 20% to 80%, no condensation
Temperature: 15°C to 28°C
Humidity: 40% to 60%
Temperature: within 2°C per hour
Humidity: within 5% per hour
Temperature: -20°C to 60°C
Humidity: 5% to 85% (No Condensation, Ink unfilled)
Chapter 2 :Product Overview
AP-75730, Rev. 2.1, 19/01/2009