Installation Environment; Installation Environment Requirements - MUTOH Blizzard Installation Manual

Mutoh blizzard plotter
Hide thumbs Also See for Blizzard:
Table of Contents

Advertisement

1 INSTALLATION ENVIRONMENT

It is very important that the installation environment fulfils following conditions to obtain stable print quality.

1.1 INSTALLATION ENVIRONMENT REQUIREMENTS

Choose a place for printer installation following the requirements in the table below.
Area
65" model
90" model
Floor loading capability
Electrical
Voltage
Frequency
Capacity
In order to protect the printer for over currents, short circuits and earth faults, the building
installation should be equipped with an automatic breaker double pole of 20 A and an earth
leakage switch of 300 mA.
Ambient
Recommended
conditions
working
environment
Operational
conditions for mild/
eco- solvent ink.
Rate of change
Storage and
transport conditions
N
OTES
A
VOID THE FOLLOWING TEMPERATURE AND HUMIDITY CONDITIONS
APPEAR DIFFERENTLY FROM WHAT YOU EXPECT
ο
P
LACES WHERE SUDDEN CHANGES IN TEMPERATURE AND HUMIDITY ARE EXPECTED
THE CONDITION IS WITHIN THE RANGE WRITTEN ABOVE
ο
P
LACES WHERE DIRECT SUNLIGHT OR EXCESSIVE LIGHTING ARE EXPERIENCED
ο
P
LACES WHERE AIR CONDITIONERS BLOW DIRECTLY
MUTOH
RECOMMENDS THAT THE PRINTER IS INSTALLED IN A PLACE WHERE AIR CONDITIONING CAN BE
.
ADJUSTED EASILY
I
F THE RECOMMENDED WORKING ENVIRONMENT CANNOT BE MET AND OUTPUT QUALITY ISSUES ARISE
BEST APPROACH TO MINIMISE THE EFFECTS IN THIS CASE IS TO REDUCE THE OUTPUT SPEED
WE RECOMMEND SWITCHING FROM
23,5 m² or larger (please refer to chapter "Required Space")
25,7 m² or larger (please refer to chapter "Required Space")
2940Pa (300kg/m²) or more
65"
AC 100-120V
AC 220-240V
60/50Hz
AC100V-120V : 11 A
AC220V-240V : 5.5 A
Temperature: 23°C
Humidity: 55%, without condensation
Temperature: 20°C - 30°C
Humidity: 40% to 65%, without condensation
Temperature: No more than 2°C per hour
Humidity: No more than 5% per hour
Temperature: 4°C to 50°C
Humidity: 40 to 80%, without condensation (When ink has been
discharged.)
:
360
360
540
720
X
DPI TO
X
9
Installation Guide Blizzard
90"
AC 100-120V
AC 220-240V
60/50Hz
AC100V-120V : 12 A
AC220V-240V : 6 A
.
O
,
THERWISE
PRINTED IMAGES MAY
.
.
720
720
.
DPI OR TO
X
DPI
AP-75261 – Rev. 2.0 – 19/12/07
,
EVEN THOUGH
.
,
THE
. I
,
N SUCH A CASE