7.1.2 Cannot generate graphics.

(1) Do not actuate at all after power activation
Possible cause
1 Is the power cable connected to the plug?
Is the AC power supply set for the specified
2
voltage?
The front cover is open, or media hold lever is
3
up.
4 Is the waste fluid tank fully inserted?
(2) Does not work after setting the media
Possible cause
1 The front cover is open, or media hold lever is up.
2 The media is not loaded straight into the plotter.
3 Are the ink cartridges inserted?
4 Are you using dedicated media?
Is the plotter being used in an environment other
5
than the one specified, such as in direct sunlight?
(3) An error is displayed and details not printed after sending data from the computer
Possible cause
1 Is the type of computer selected correctly?
Are the interface requirements and command
2
mode the same on the computer side and plotter
side?
(4) Cannot use the computer in online mode via LAN
Possible cause
Is the network interface cable connected
1
correctly?
2 Is network setting configured correctly?
Are the plotter's network settings correctly
3
configured?
Does the Data light on the operation panel
4
switch on after sending graphics data from the
computer?
Cannot use the computer in online mode via USB
(5)
Possible cause
1 Is the USB cable correctly connected?
Does the Data light on the operation panel
2
switch on after sending graphics data from
the CAD?
Is the type of command currently set up, the
3
same as the one on the CAD and driver side?
User's Guide DrafStation and Drafstation Pro
Remedy
Connect the power cable.
Connect the cable to another
outlet.
Close the front cover.
Lower the media hold lever.
Fully insert the waste fluid tank. "Replacing waste fluid tank"
Remedy
Close the front cover.
Lower the media hold lever.
Load the media straight.
Insert the ink cartridges.
Use dedicated media.
Only use the plotter in an
environment that is specified for
use.
Remedy
Check that the settings on the
computer side and plotter side are
the same.
Remedy
Connect the network interface cable
correctly.
Configure network settings correctly. "Network Menu"
Match this product's network settings
with the computer side environment.
If the Data light does not switch on,
contact the computer manufacturer.
Remedy
Connect the USB cable correctly.
If the Data light does not switch on,
contact the CAD or computer
manufacturer.
Match the command setting of the plotter
to the environment of the CAD and driver.
129
Chapter 7: Troubleshooting
Reference
"Power cable connection"
"Power cable connection"
"Handling and installing
media"
Reference
"Handling and
installing media"
"Handling and
installing media"
"Installing ink
cartridges"
"Media"
"Installation guide"
Reference
"Connecting the
plotter to PC"
"Setting the plotter
driver"
Reference
"Connecting network
interface cable"
"System requirements"
--
Reference
"Connecting the
USB cable"
--
"Command