HW0481893
4.1
Grounding
Follow the local regulations and electrical installation standards for grounding. The recom-
mended grounding wire size is 5.5mm
For grounding, connect the ground wire directly to the manipulator as in "Fig. 6 Grounding
Method".
• Do not use this line in common with other ground wires or grounding electrodes for other
NOTE
electric power, motor power, welding devices, etc.
• Where metal ducts, metallic conduits, or distributing racks are used for cable laying,
ground in accordance with the local electrical installation standards.
2
at minimum.
5.5mm
2
or more
Bolts M8 (for grounding)
Delivered with the manipulator
Fig. 7 Gounding Method
4-2
4.1 Grounding
View A