IN
Program 82
SA
SB
Description
Use Program 82-04 : Analogue Station Initial Data Setup to define the various basic timers for the 308M/308ME
Card.
Input Data
Prog. No.
82-04-01
Companding method type
82-04-02
Ringing frequency
82-04-03
Maximum Break Time
82-04-04
Minimum Break Time
82-04-05
Minimum Make Time
82-04-06
Maximum Make Time
82-04-07
Maximum Hook Flash Time
82-04-08
Minimum Hook Flash Time
82-04-09
Minimum Ground Flash Time
82-04-10
Maximum Off-Hook Time
82-04-11
No detection time after Off-Hook
82-04-12
No detection time after pulse dial detection
82-04-13
Loop disconnect time, Reversal time
82-04-14
Ring, Message wait period time
Conditions
None
Feature Cross Reference
None
:
Basic Hardware Setup for Extension
82-04: Analogue Station
Item
343
Initial Data Setup
Input Data
0 : μ-law
1 : A-law
0 : 25Hz
1 : 20Hz
2 : 16Hz
1-255(5ms-1275ms)
1-255(5ms-1275ms)
20 (100ms)
1-255(5ms-1275ms)
1-255(5ms-1275ms)
20 (100ms)
1-255(5ms-1275ms)
21 (105ms)
1-255(5ms-1275ms)
200 (1000ms)
1-255(5ms-1275ms)
21 (105ms)
1-255(5ms-1275ms)
21 (105ms)
1-255(5ms-1275ms)
60 (300ms)
1-255(5ms-1275ms)
70 (350ms)
1-255(5ms-1275ms)
60 (300ms)
1-255(5ms-1275ms)
150 (750ms)