NEC Aspila Topaz Programming Manual page 236

Intelligent hybrid system
Hide thumbs Also See for Aspila Topaz:
Table of Contents

Advertisement

Program 25: DID/DISA Setup
25-02: DID/DISA Talkie
Description
Use Program 25-02 : DID/DISA Talkie to assign the VRS message number to be used as the Automated Attendant
Error Message for each trunk which is assigned as a DID/DISA.
Input Data
Trunk Port Number
Day/Night
Talkie Type
Mode
0 : No Talkie
1 : VRS
1-8
2 : ACI
3 : SLT
Conditions
None
Feature Cross Reference
Direct Inward System Access (DISA)
Telephone Programming Instructions
To enter data for Program 25-02(DID/DISA Talkie):
1. Enter the programming mode.
2. Enter 25 02
25-02-01TrkPrt1
Mode1 Talkie= 0
3. Enter the number of the item you want to program.
25-02-xxTrkPrtxx
xxxxx
4. Select the Trunk port number to be programmed by pressing the FLASH or the VOLUME▲ or VOLUME▼
keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you've exited that series's programming section.
Programming Manual
Additional data
1 : VRS 01-48 (VRS Message No.)
2 : ACI
1-4 (ACI Group No.)
3 : SLT
1-32 (Station Group No.)
228
IN
SA
SB
1-51
Related
Default
Program
0

Hide quick links: