Description
Use Program 24-01 : System Options for Hold to define the system options for the Hold feature
Input Data
Prog. No.
24-01-01
Hold Recall Time
A call on Hold recalls the extension that placed it on
Hold after this interval. This timer works with the
Hold Recall Callback Timer (Item 2).
24-01-02
Hold Recall Callback Time
A trunk recalling from Hold or Park rings an
extension for this interval. This timer works with
timer 01 (Hold Recall Time) or timer 06 and 07 (Park
Recall Time). After this interval, the system invokes
the Hold recall time again. Cycling between timer 01
and 02 and 06 and 07 continues until a user answers
the call.
24-01-03
Exclusive Hold Recall Time
A call left on Exclusive Hold recalls the extension
that placed it on Hold after this interval.
24-01-04
Exclusive Hold Recall Callback Time
An Exclusive Hold Recall rings an extension for this
interval. If not picked up, the call goes back on
System Hold.
24-01-05
Forced Release of Held Call
Depending on the setting of Program 14-01-16, the
system disconnects calls on Hold longer than this
interval
24-01-06
Park Hold Time – Normal
A call left parked longer than this interval recalls the
extension that initially parked it.
24-01-07
Park Hold Time – Extended
A call left parked longer than this interval recalls the
extension that initially parked it.
Conditions
None
Feature Cross Reference
Hold
Park
Program 24: Hold/Transfer Setup
24-01: System Options for Hold
Item
217
Input Data
Default
0-64800(Sec.)
90
0-64800(Sec.)
30
0-64800(Sec.)
90
0-64800(Sec.)
30
0-64800(Sec.)
64800
0-64800(Sec.)
90
0-64800(Sec.)
300