Use Program 15-13 : Loop Keys to assign the Loop Key data for each keyset telephone. Loop Keys can be
incoming, outgoing or both ways. Outgoing Loop Keys use the Data 1 options. Incoming Loop Keys use the Data 2
option. Both Way Loop Keys use both the Data 1 and Data 2 options.
Input Data
Extension Number
Key Number (KTS with DLS)
Prog. No.
Item
15-13-01
Data 1(Outgoing)
Option
15-13-02
Data 2(Incoming)
Option
Default
Programmable Function Key No. : 01-46
Data 1 (Outgoing) Option
Data 2 (Incoming) Option
Conditions
None
Feature Cross Reference
Loop Key
Program15: Extension Basic Setup
(0- Assigns the Loop Key for ARS, 1-25- Assigns
(0- Assigns the Loop Key to all trunk groups, 1-25-
Assigns the Loop key to the trunk group specified)
: 0 (Assigns the Loop Key for ARS)
: 0 (Assigns the Loop Key to all trunk groups)
119
15-13: Loop Keys
Max. 4 digits
01-46
Input Data
0-25
the Loop Key to the trunk group specified)
0-25
Programming Manual