3. Re-Installation(COLD Start)
This mode may be selected in case of re-installation from factory setting. The existing System
Software(stored to the Flash Memory) will be remained, and the existing Customer data(stored to the
RAM) will be cleared.
• When the system requires to re-install from factory setting, the operation is as follows;
1) SW1 on the 308M unit will be set at the left side to "C" and turn System Power Switch to ON.
2) Wait until 1-2 minutes, LED2 (RUN) is going to be lit and the Key Telephone's display shows Time
& date with Extension number.
4. Re-start(HOT Start)
This mode may be selected in case of re-start(System Reset). The existing System Software (stored to
the Flash Memory) and the Customer data(stored to the RAM) will be remained.
• When the system requires to Re-Start(System Reset), the operation is as follows;
1) SW1 on the 308M unit will be set at the right side to "H" and turn System Power Switch to ON.
2) Wait until 1-2 minutes, LED2(RUN) is going to be lit and the Key Telephone's display shows Time &
date with Extension number.
Before Programming
Before the programming, the Main Software Version and Port Number can be checked by the Display Key
Telephone.
 
1. Confirmation of the Software Version
The Software Version can be checked by "OPAC" key and "Dial 3"(by On-Hook condition) or PRG90-
16-01.
2. Confirmation of the Port Number
The Own Port Number can be checked by Press "CHECK" key and "CALL" key (by On-Hook
condition). The Other Port Number also can be checked by Press "CHECK" key and Dial Destination
Extension Number (by On-Hook condition).