IN
SA
SB
Description
Use Program 20-17 : Operator's Extension to designate an operator. When an extension user dials "0" or "9"
(defined by Program 11-01 Type 5), calls go to the operator selected in this program.
If you don't assign an extension in Program 90-11-01, system alarms appear on the extension assigned in this
option.
Input Data
Operator Number
Prog. No.
20-17-01
Operator Extension Number
20-17-02
Operator Console
Conditions
None
Feature Cross Reference
Intercom
Telephone Programming Instructions
To enter data for Program 20-17(Operator's Extension):
1. Enter the programming mode.
2. Enter 20 17
20-17-01 Operat1
Oper.Ext.No.
3. Enter the number of the item you want to program.
20-17-xxOperatx
xxxxx
4. Select the Operator number to be programmed by pressing the FLASH or the VOLUME
VOLUME
keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you've exited that series's programming section.
Program 20: System Option Setup
Item
Max. 4 digits
0 : Normal KTS
1 : Special Operator Console
155
20-17: Operator's Extension
1-8
Input Data
Programming Manual
Related
Default
Program
No
11-01
setting
0