Description
Use Program 15-06 : Trunk Access Map for Extensions to define the trunk access map for each extension. An
extension can only place outgoing calls on trunks to which it has outgoing access. Use Program 14-07 to define the
available 51 access maps.
Input Data
Extension Number
Day/Night Mode
1-8
Conditions
None
Feature Cross Reference
Central Office Calls, Answering
Central Office Calls, Placing
Telephone Programming Instructions
To enter data for Program 15-06(Trunk Access Map for Extensions):
1. Enter the programming mode.
2. Enter 15 06
15-06-01 TEL200  
Mode1 Acc-Map1
3. Enter the number of the item you want to program.
15-06-xx TELxxxx
xxxxx
4. Select the Extension number to programmed by pressing the FLASH or the VOLUME▲ or VOLUME▼ keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you've exited that series's programming section.
Program15: Extension Basic Setup
15-06: Trunk Access Map for Extensions
Trunk Access Map No.
1-51
105
Max. 4 digits
Default
Related Program
1
14-07