Description
Use Program 20-06 : Class of Service for Extensions to assign a Class of Service to an extension.
There are15 Classes of Service that can be assigned. To specify the options in each Class of Service, refer to
Programs 20-07 through 20-13. You make eight entries for Program 20-06, one for each Night Service Mode.
Input Data
Extension Number
Day/Night Mode
1-8
Conditions
None
Feature Cross Reference
Class of Service
Telephone Programming Instructions
To enter data for Program 20-06(Class of Service for Extensions):
1. Enter the programming mode.
2. Enter 20 06
20-06-01 TEL200  
Mode1 ClassNo.1
3. Enter the number of the item you want to program.
20-06-xx TELxxxx
xxxxx
4. Select the Extension number to be programmed by pressing the FLASH or the VOLUME
keys.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press DC once to enter a new item number.
OR
Press DC until you've exited that series's programming section.
Program 20: System Option Setup
20-06: Class of Service for Extensions
Class of Service Extensions
1-15
133
Max. 4 digits
Default
All Extensions are Class 1.
or VOLUME