Process Data† Inputs Ep-5112 - Emerson PACSystems RSTi-EP User Manual

Remote i/o system
Hide thumbs Also See for PACSystems RSTi-EP:
Table of Contents

Advertisement

User Manual
GFK-2958J
Name
Channel error
Channel error
Channel error
Channel 0 error
Channel 2 error
to
Channel 31
error
Time stamp
Process Data† Inputs EP-5112
Byte
Format
IB0 ... IB3
Double word
IB4 ... IB7
Double word
IB8
Word
IB9
IB10
Word
Detailed Description of I/O Modules
Bytes
Bit
1
2-7
8
8 – 15
9
16 – 23
10
24 – 31
0-1
2
11
3
4-7
13
to
0-7
42
43-46
Name
Bit
Counter 0:
Counter value
Counter 1:
Counter value
IX8.0
IX8.1
IX8.2
IX8.3-8.4
IX8.5
IX8.6
IX8.7
Counter 0:
IX9.0
Counter status
IX9.1
IX9.2
IX9.3
IX9.4
IX9.5
IX9.6-9.7
IX10.0
IX10.1
Counter 1:
Counter status
IX10.2
IX10.3 - 10.4
Description
Error at channel group 1
Reserved
Reserved
Reserved
Reserved
Reserved
Overflow/underflow/end value
Comparison value reached
Reserved
Reserved
Time stamp [μs] (32-bit)
Function when active
Reserved
Comparison bit released
SW gate active
Reserved
Internal gate active
Comparison bit active
Counter direction down
Counter direction up
Comparison condition
met
End value reached
Overflow performed
Underflow performed
Zero crossing performed
Reserved
Reserved
Comparison bit released
SW gate active
Reserved
Chapter 5
Oct 2019
Default
0
0
0
0
0
0
0
Remark
Counter 0: current count
value
Counter 1: current count
value
190