3.2
3.4
Potential distribution modules
EP-711F
Status LED
EP-710F
EP-751F
Status LED
EP-750F
EP-700F
Status LED
Safety modules
EP-1901
Status LED
LED Indicators and Troubleshooting
Channel error or communication error on the
system bus, or there is an error in the supply
voltage
Red:
Supply voltage of the feed in plug < 18Vdc
Red:
Damage of internal fuse
Red:
Error in supply voltage of the input path
Red:
Error in supply voltage of the input path
Off:
No supply voltage
Red:
Module has not been snapped properly
Error in the supply voltage
Channel error
Overload at the OSSD output level
External feed-in recognized from field
side
Internal error detected
Check the channel error, check
the supply voltage
Check supply voltage of feed in
plug
Replace module
Check that the module has been
snapped into place properly
Check the supply voltage
Check that the module has been
snapped into place properly
Check the supply voltage
Check that the module has been
snapped into place properly
Check that the module has been
snapped into place properly
Check the supply voltage
check +24 V input current path
Check voltage on plug 4.3; in
case of cascading 0 V might be
properly, therefore this is not an
error
Check channel error
Remove cross connection at
OSSD
Measure voltage at OSSD pin
(4.3) vs. GND (4.4).
If a voltage is present, check the
wiring.
Attention: safety hazard! Shut
down the system and prevent it
from switching on again.
Module might have switched off
caused by overtemperature;
check the temperature inside the
switch cabinet
Perform a cold start within 24
hours
If the error has not been fixed,
send the module to Emerson for
a technical examination.