Technical Data; Communication Interfaces - Emerson CSI 6500 Quick Start Manual

Machinery health monitor a6825, interface card 6x rs485 to ethernet tcp/ip
Hide thumbs Also See for CSI 6500:
Table of Contents

Advertisement

Available languages

Available languages

Product Information / Produktinformation A6825
Interface Card 6 x RS 485 to Ethernet TCP/IP
Any other information, e. g. shielding and grounding, configuration of the interface card, etc.,
can be found in the direction for use "Interface Card 6 x RS 485 to Ethernt TCP/IP A6825" order
number: 6110−90092.
1.6

Technical Data

Only specifications with tolerances or limit values are guaranteed. Data without tolerances or
without error limits are informative data and not guaranteed. Technical modification, especially
of the software, are subject to changes without notice.

1.6.1 Communication interfaces

RS 485 interface
6 interface bus−lines, max 31 MMS 6000 monitors per bus line.
Bus line 1 (Com 1)
Bus line 2 (Com 2)
Bus line 3 (Com 3)
Bus line 4 (Com 4)
Bus line 5 (Com 5)
Bus line 6 (Com 6)
Transmission mode
Transmission rate
Interface TCP/IP Network
Connection
Data transmission standard:
d4 (A1) / z4 (B1) / b4 (GND)
d12 (A2) / z12 (B2) / b12 (GND)
d14 (A3) / z14 (B3) / b14 (GND)
d16 (A4) / z16 (B4) / b16 (GND)
d18 (A5) / z18 (B5) / b18 (GND)
d20 (A6) / z20 (B6) / b20 (GND)
RS 485 epro protocol
38,4 kBaud; 57,6 kBaud or 115,2 kBaud
RJ 45 socket (Front plate)
ETHERNET 10 base T
Page 12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents