Figure 6-13 Main Options In The Web-Management System Window - Alcatel-Lucent 7330 Product Information Manual

Intelligent services access manager
Hide thumbs Also See for 7330:
Table of Contents

Advertisement

Procedures using CLI interface for Package C ONTs
Not applicable.
Procedures using butt set
Not applicable.
6.8
Retrieving RSSI
The RSSI is the recorded measurement of the ONT receive optical signal at 1490 nm
in dBm. This feature is available for RSSI-capable ONTs only.
This section shows you how to retrieve the RSSI measurement for an ONT.
Prerequisites
The prerequisites are:
The user access level of the ONT is read only or read-write.
The ONT is RSSI capable.
The steps to access the interface are completed.
Procedures using HTTP interface
The following procedure provides the steps to view the RSSI measurement for an
ONT using the HTTP interface.
Procedure 6-17 To view RSSI
1
2
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a
3FE 54199 AAAA TCZZA
See Procedure
6-1
for HTTP interface using the first Ethernet port.
See Procedure
6-4
for CLI interface using the first Ethernet port.
From the Web-Management System window, click on the States Management
tab, as shown in Figure 6-13.

Figure 6-13 Main options in the Web-Management System window

The ONT status window opens with the ONT states and their current status, as
shown in Figure 6-10.
Click on the RSSI tab. The RSSI window opens with the current RSSI measurement,
as shown in Figure 6-14.
Edition 01 ONT Product Information Guide
6 — ONT management using an ONT interface
March 2011
6-29