Alcatel-Lucent 7330 Product Information Manual page 227

Intelligent services access manager
Hide thumbs Also See for 7330:
Table of Contents

Advertisement

Analog local network profile
Table
is yes, then TL1 can be used to configure equivalent parameters on systems
supporting OMCIv2.
Table 5-10 Analog local network profile provisioning parameters
Parameter
Description
permanent_time
The duration, in seconds, of the
r
"permanent" timer (sometimes known
as the "start dial" timer). This timer
starts when an off-hook condition is
detected on the POTS line, and if it
expires before any digits are received
from the POTS line, permanent
treatment is applied to the line. This is
an optional parameter. This is a
non-negative integer and the value is
expressed in seconds. The default
value is 16.
interdigit_timer
The duration, in seconds, of the
standard interdigital timer. This timer
starts after a digit is received from the
analog line interface, and if it expires
before another digit is received,
dialing is assumed to be completed.
This is an optional parameter. This is a
non-negative integer and the value is
expressed in seconds. The default
value is 16.
critical_timer
The duration, in seconds, of the
"critical" interdigital timer. This timer
starts at a point in digit collection
specified by the dialing pattern, and if
it expires before another digit is
received, dialing is assumed to be
completed. This is an optional
parameter. This is a non-negative
integer and the value is expressed in
seconds. The default value is 4.
timed_release
The duration, in seconds, of the Timed
Release timer. To end a conversation,
the local or remote subscriber hangs
up. If the local subscriber hangs up,
BYE is sent to the softswitch
immediately unless this was a
termination end of the call. If the local
call was the termination call, BYE is
not sent and the idle state is entered
until the re-answer timer expires or
BYE is received. The re-answer timer is
configured using the timed_release
parameter.
This is an optional parameter. This is a
non-negative integer and the value is
expressed in seconds. The default
value is 10 seconds.
(1 of 3)
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a
3FE 54199 AAAA TCZZA
5-10
lists the analog local network profile parameters. When OMCIv2 support
Edition 01 ONT Product Information Guide
Mode
Mode
Device
1
2
Y
Y
All
Y
Y
All
Y
Y
All
Y
Y
All
March 2011
5 — VoIP overview
OMCIv2
TL1 or CLI
support?
parameters
Yes but no
N/A
TL1 or CLI
developed
Value is
derived
from
FTP/defau
lt line
profile.
No, value
N/A
is derived
from
FTP/defau
lt line
profile.
Yes but no
N/A
TL1 or CLI
developed
Value is
derived
from
FTP/defau
lt line
profile.
Yes
TL1 using
RLSTIMER using
ed-ontvoiceport
sip
CLI using
rlstimer
using
configure voice
ont
voice-sip-port
5-27

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7302

Table of Contents