NTP 107 — Replace an I-010G-B indoor ONT
7
8
Figure NTP 107-2: Power connector pin configuration for I-010G-B indoor ONTs
NTP 107-4
Connect the SC/APC adaptor to the fiber optic port (DLP 118).
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
Connect the power cable with an 8-pin Molex connector to the ONT unit.
Warning — To avoid the possibility of damage to the pins on the power
cable connector, carefully align the pins on the connector on the cable
with the pin holes in the power connector on the ONT before making the
connection. The pin hole configuration in the power connector on the
ONT is shown in Figure
Molex connector is shown in Figure
Figure
NTP 107-2
shows the power connector on an I-040G-B indoor ONT. The
power connector is exactly the same and in the same location on the I-010G-B
indoor ONT.
March 2011
ONT Product Information Guide Edition 01
NTP 107-2
while the pin arrangement on the
NTP
107-3.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a