To activate an ONT using the serial number, the following is required:
•
The ONT must be provisioned at the P-OLT with its serial number, a dummy
SLID, provisioning data, and services.
•
The ONT with the corresponding serial number must be installed at the customer
site.
•
The ONT must be connected to the GPON.
To activate an ONT using the SLID, the following is required:
•
The ONT must be provisioned at the P-OLT with a dummy serial number, its
SLID, provisioning data, and services.
•
The ONT with any serial number must be installed at the customer site.
•
The SLID in the ONT must be cleared locally, if the ONT has a non-default SLID.
•
The SLID must be entered locally into the ONT.
•
The ONT must be connected to the GPON.
Activation of an ONT can also be initiated by the P-OLT automatically at regular
intervals or when one or more formerly registered and active ONTs become inactive.
In both cases, the frequency of the P-OLT polling is programmed by the user.
The SLID at the ONT can be stored in volatile or non-volatile mode. In volatile
mode, the SLID is delivered to the P-OLT in proprietary mode; in non-volatile mode,
the SLID can be delivered to the P-OLT in registration ID or proprietary mode. The
SLID can be entered in hexadecimal or alphanumeric string format. See Table
for more information about SLID settings
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a
3FE 54199 AAAA TCZZA
Note —
The ONT and its services can be preprovisioned at the
P-OLT before or after the ONT is installed.
Note —
If you are reusing an ONT that was previously configured
with a non-volatile SLID, the SLID must be reset to its default value.
If you are reusing an ONT that was previously configured with a
volatile SLID, the SLID will automatically return to its default value
when the ONT is powered off and on.
Edition 01 ONT Product Information Guide
6 — ONT management using an ONT interface
March 2011
6-10