6 — ONT management using an ONT interface
Download state
Idle
Downloading
Writing to flash
Complete
This section shows you how to check the status of a software download.
Prerequisites
The prerequisites are:
•
The user access level of the ONT is read-write.
•
The ONT is connected to the GPON.
•
The steps to access the interface are completed.
Procedures using HTTP interface
The following procedure provides the steps to check the status of the software
download from the P-OLT to the ONT using the HTTP interface.
6-38
Table 6-9 Software download states
Description
There is no download activity.
Software is being downloaded from the P-OLT to the ONT.
Software updates are being written to memory.
Software download is complete.
Note —
The ONT changes from one operational state to another as
the software download progresses, as follows:
•
SW_DLD_IDLE, when there is no software download activity
•
SW_DLD_START, when the software download is initiated
•
SW_DLD_IP, when the software download is in progress
•
SW_DLD_DONE, when the software download is complete
•
SW_DLD_FAIL, when the software download failed
See section
6.6
for more information about checking the operational
state of an ONT.
•
See Procedure
6-1
for HTTP interface using the first Ethernet port.
•
See Procedure
6-4
for CLI interface using the first Ethernet port.