Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a
3FE 54199 AAAA TCZZA
Figure NTP 100-3: B-0404-A with wall mount bracket
1
2
3
4
1
Connect up to four Ethernet cables to the RJ-45 ports (DLP 101).
Connect up to four E1/T1 cables to the RJ-48C ports (DLP 103).
If used, configure the SLID (DLP 122).
Connect the fiber optic cable.
i
Plug the OptiTap adaptor into the fiber optic port (DLP 117).
ii
Plug the SC/APC adaptor into the fiber optic port (DLP 118).
Warning — Be careful to maintain a bend radius of no less than 1.5
inches (3.8 cm) when connecting the fiber optic cable. Too small of a
bend radius in the cable can result in damage to the optic fiber.
If the B-0404-A is powered using:
a
a power converter, go to step 11.
b
a UPS, go to step 12.
Install the power converter.
i
Connect the ac power cable to the power converter (1AF 01226 AK), and plug
the power converter into the electric outlet as shown in Figure
Note — Observe the following:
The power converter must be located within 5 ft (1.5 m) of the
device.
The power converter must be located within 6 ft (1.8 m) of an
electrical outlet.
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 2 A.
Edition 01 ONT Product Information Guide
PON
2
3
4
March 2011
NTP 100 — Install a B-0404-A
20009
NTP
100-4.
NTP 100-5