NTP 107 — Replace an I-010G-B indoor ONT
Safety information
Read the following safety information before replacing the unit.
Procedure
Use this procedure to replace an I-010G-B indoor ONT.
1
2
3
NTP 107-2
Danger — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when removing the fiber access cover of the indoor ONT.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
Note — Observe the following:
•
The indoor ONT should be installed in accordance with the
applicable requirements of the NEC or CEC. Local authorities and
practices take precedent when there is conflict between the local
standard and the NEC or CEC.
The indoor ONT must be installed by qualified service personnel.
•
Indoor ONTs must be installed with cables that are suitably rated
•
and listed for indoor use.
See
I-010G-B detailed
•
temperature ranges for ONTs.
Deactivate the ONT services (DLP 124).
If you are using the SLID feature, this step is not required. The ONT and the
services can remain in service (IS).
Power down the ONT unit by using the ON/OFF power switch.
Disconnect the Ethernet, fiber optic, and power cables from the ONT (DLP 125).