Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.42a
3FE 54199 AAAA TCZZA
Figure NTP 101-1: B-0404-A connections
LINE 1
LINE 2
LINE 3
E1/T1
(RJ-48C)
Replace the old unit with a new unit.
Connect up to four Ethernet cables to the RJ-45 ports (DLP 101).
Connect the E1/T1 cable assembly to the RJ-48C ports (DLP 103).
If the B-0404-A business ONT is powered using:
a
a power converter, go to step 7.
b
a UPS, go to step 8.
Install the power converter.
i
Connect the ac power cable to the power converter (1AF 01226 AK), and plug
the power converter into the electric outlet as shown in Figure
Note — Observe the following:
The power converter must be located within 5 ft (1.5 m) of the
device.
The power converter must be located within 6 ft (1.8 m) of an
electrical outlet.
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 2 A.
Edition 01 ONT Product Information Guide
LINE 4
1
2
3
Ethernet ports
(RJ-45)
March 2011
NTP 101 — Replace a B-0404-A
UPS
PON
4
Power
Fiber optic
connection
port
19868
NTP
101-2.
NTP 101-3